Triconex 3636R Relay Output Module
Technical ParametersVOGI
Output type: 32 independent dry contact outputs
Voltage range: 125V AC/DC maximum, minimum load is 10mA, 5V DC
Current load: Maximum 2A, suitable for driving solenoid valves, contactors and other devices
SIL level: SIL3 certified, compliant with IEC 61508 and IEC 62061 standards
Temperature range: -40℃ to 75℃
Operating voltage: 24V DC
Key FeaturesVOGI
Triple Module Redundancy Architecture
Triconex 3636R uses TMR technology to automatically detect and correct errors through three independent circuits running in parallel and a "two out of three" voting mechanism, ensuring that the system can continue to operate under single-point failure without the risk of single-point failure.
High reliability and safety
Intelligent diagnosis: Triconex 3636R has a built-in fault detection function that can monitor module status in real time, quickly locate and isolate faults, and reduce downtime.
Remote management: Triconex 3636R supports remote monitoring and configuration, which is convenient for real-time adjustment of system parameters and diagnosis.
Flexible compatibility
Multi-system integration: Triconex 3636R is compatible with a variety of PLCs, DCSs (such as Honeywell, Foxboro) and SCADA systems, and can be seamlessly integrated into the existing automation architecture.
Modular design: Triconex 3636R supports expansion and upgrades, and can flexibly configure the number and type of input and output points according to application requirements.
Simplified maintenance
Online maintenance: Triconex 3636R supports hot swapping, allowing modules to be replaced while the system is running, reducing maintenance complexity and costs.
Self-diagnosis function: Providing detailed fault information, Triconex 3636R facilitates quick repair and preventive maintenance.
Freight Estimation(Part Of The Area)VOGI
Destination |
Freight |
Middle East |
$80 |
Southeast Asia |
$35 |
South Asia |
$105 |
South Africa |
$96 |
Europe and USA |
$57 |
Russia |
$110 |
APPLICATIONVOGI
Oil and gas
Emergency shutdown (ESD), wellhead safety control, pipeline leakage protection
Triconex 3636R advantages: triple redundant (TMR) architecture, resistant to harsh environments (-40℃~75℃), in compliance with API safety standards.
Chemical / Petrochemical
Reactor safety interlock, fire linkage, distillation tower protection
Triconex 3636R advantages: SIL3 certification, anti-false operation "three out of two" voting, long-life contacts (more than tens of thousands of times).
Electric power
Turbine emergency shutdown (ETS), substation circuit breaker control, energy storage system safety cut-off
Advantages: hot-swappable maintenance, support for AC/DC mixed loads (125V AC/DC).
Manufacturing / Special scenarios
Automated production line emergency stop loop, sterile workshop control, rail transit fire linkage