Vibro-Meter IOC16T 200-565-000-013 INPUT/OUTPUT CARD
Technical ParametersVOGI
Part Number: 200-565-000-013
Function: 16 Form-C relay outputs plus 4 digital inputs
Form Factor: VM600 6 U card, hot-swappable under power
Power Supply: +24 V DC from VM600 backplane, nominal 150 mA
Relay Outputs:
16 independent Form-C (SPDT) dry-contact relays
Contact rating: 2 A @ 250 V AC or 2 A @ 30 V DC
Minimum switching: 10 mA @ 5 V DC
Digital Inputs:
4 programmable status/inhibit inputs (24 V DC logic)
Opto-isolated, accepts 0–30 V DC
Backplane Interfaces:
Raw-Bus for protection-card alarm routing
OC-Bus for over-current or external logic gating
Environmental:
Operating temperature: –25 °C to +65 °C
Storage temperature: –40 °C to +85 °C
Shock: 6 g, 11 ms; Vibration: 5–35 Hz @ 0.15 mm / > 35 Hz @ 1 g
Humidity: up to 95 % non-condensing
Key Features
VOGI
High-Density Relay Outputs
Sixteen Form-C relays enable simultaneous alarm, warning and trip contacts for multiple channels or machines.
Flexible Logic Inputs
Four status/inhibit lines permit external interlocks, maintenance bypass or emergency-stop integration.
Configurable via Software
Alarm levels, timing delays, latching behavior and input–output mappings set through VibroSight or rack-front setup tools.
Redundant & Segregated Busing
Separate Raw-Bus and OC-Bus paths ensure protection logic remains isolated from plant logic and power-system disturbances.
Hot-Swap Capability
Maintenance or card replacement can occur without shutting down the entire rack, minimizing plant downtime.
Robust Industrial Design
Meets IEC shock, vibration and EMI/EMC standards for reliable operation in heavy-industry environments
Freight Estimation(Part Of The Area)VOGI
Destination |
Freight |
Middle East |
$42 |
Southeast Asia |
$15 |
South Asia |
$55 |
South Africa |
$47 |
Europe and USA |
$27 |
Russia |
$50 |
Applications
VOGI
Turbine Generator Rack
Alarm contacts feed generator control panels for overspeed, vibration or temperature faults; digital inputs accept plant-wide Trip-Enable or manual-reset signals.
Process-Line Safety Interlocks
IOC16T’s form-C relays integrate with safety PLCs to shut off valves or isolate sections of a petrochemical line based on VM600 protection-card outputs.
Aggregated Plant-Wide Status
Status inputs combine remote sensor health signals (e.g., fieldbus watchdogs or UPS fail) to block false trips; relay outputs reflect integrated protection status back to SCADA.