Vibro-Meter IQS450 204-450-000-001 A1-B21-H10-I0
Technical ParametersVOGI
Part Number & Configuration
204-450-000 001 A1-B21-H10-I0
A1: Optimized for TQ401-series probes (0–4 mm eddy-current).
B21: 4–20 mA loop output (4 mA = 0 mm; 20 mA = 4 mm).
H10: 10 m integral coaxial cable to probe.
I0: Standard (no internal IS barrier).
Probe Excitation & Input
Drive Voltage: –20 V DC to –32 V DC (≈ 13 mA) to excite the TQ401 probe.
Measuring Range: 0–4 mm linear span (±1 % over full scale with matched probe).
Frequency Response: DC 20 kHz (captures both slow deflection and high-frequency vibration).
Output Signals
4–20 mA Loop (B21):
Scaled 4 mA @ 0 mm, 20 mA @ 4 mm; drive capacity up to 800 Ω.
Provides a fail-safe “low-current” indication (< 3 mA) on open-circuit.
0–10 V Raw Bus:
Buffered, proportional to gap (0 V @ 0 mm → 10 V @ 4 mm).
Output impedance ≈ 500 Ω; available on the VM600 raw bus for downstream cards (e.g., MPC4, CMC16).
Environmental & Mechanical
Cable: 10 m PTFE-insulated, stainless-steel-braided coax.
Operating Temp.: –25 °C to +65 °C; Storage: –40 °C to +85 °C.
Shock: 6 g half-sine, 11 ms.
Vibration: 5–35 Hz @ 0.15 mm; > 35 Hz @ 1 g.
Humidity: Up to 95 % non-condensing.
Mounting: Hot-swappable in any VM600 backplane slot.
Safety & Approvals
Designed for safe-area use; pairs with external IS barriers for hazardous zones.
Key Features
VOGI
Dual-Output: 4–20 mA + 0–10 V
4–20 mA loop output for long-distance or intrinsically safe circuits; raw 0–10 V on the VM600 bus for protection cards or PLC analog inputs.
Fail-safe behavior: < 3 mA indicates probe open/short.
Wideband Precision
Flat DC–20 kHz response supports both slow shaft-center tracking and high-frequency vibration detection without external filtering.
≤ 1 % linearity over 0–4 mm ensures accurate gap measurement.
Extended Probe Cable (10 m)
Built-in, low-capacitance 10 m cable reduces signal attenuation and preserves bandwidth in large machinery rooms.
Stainless-steel braid and PTFE insulation for chemical and mechanical resistance.
Integrated Fault Detection
On-board diagnostics monitor probe continuity; open/short faults drive loop current < 3 mA and set raw-bus output to a defined “fault” level.
Front-panel LED reports “OK” vs. fault status at a glance, even during hot-swap.
Modular, Hot-Swap Design
VM600 6 U form factor; can be inserted/removed under power without disrupting the rest of the rack.
Conformal-coated PCB option for high-humidity or corrosive environments.
Seamless VM600 Integration
Rear-plane connection supplies power, raw bus, and loop-output routing.
Compatible with VibroSight and VM600 protection/monitoring cards (MPC4, CMC16).
Freight Estimation(Part Of The Area)VOGI
Destination |
Freight |
Middle East |
$42 |
Southeast Asia |
$15 |
South Asia |
$55 |
South Africa |
$47 |
Europe and USA |
$27 |
Russia |
$50 |
Applications
VOGI
North American combined cycle power station
Applied to GE 7FA gas turbine bearing vibration monitoring, integrated VM600 system to achieve automatic trip protection, annual fault downtime reduced by 40%
North Sea offshore wind power project
Deployed in Siemens Gamesa 6MW wind turbine gearbox, transmit vibration data to SCADA system via RS-485, support remote diagnosis.