Vogi International Trading Co., Ltd.
Email: sales4@vogi-interl.com/sales9@vogi-interl.com
Tel: +86 19065187381
Leave Your Message
Vibro-Meter IQS450 204-450-000-001 A1-B23-H10-I0 Signal Conditioner
VIBRO-METER

Vibro-Meter IQS450 204-450-000-001 A1-B23-H10-I0 Signal Conditioner

  • Brand Vibro meter
  • Module Number IQS450
  • Ordering Number 204-450-000-001 A1-B23-H10-I0
  • Country Of Origin Switzerland
  • Dimension 160 × 160 × 120 mm
  • Weight 0.5 kg
  • HS Code 9033000090
  • Condition Brand New
  • Certificate COO TEST REPORT WARRANTY LETTER
  • Warranty 12 Months
  • Inventory Qty 5
  • Payment Term T/T

Technical ParametersVOGI

Part Number & Configuration
204-450-000 001 with suffix A1-B23-H10-I0
A1: Optimized for TQ401-series probes (0–4 mm eddy-current)
B23: Single 4–20 mA loop output only (no 0–10 V bus output)
H10: 10 m integral coaxial cable to probe
I0: Standard (no built-in intrinsic-safety barrier)
Probe Excitation & Input
Drive Voltage: –20 V to –32 V DC (≈ 13 mA) to excite the TQ401 probe
Measuring Range: 0–4 mm linear span (≤ 1 % non-linearity with matched probe)
Frequency Response: DC to 20 kHz (–3 dB)
Output
4–20 mA Loop:
Scaled: 4 mA @ 0 mm → 20 mA @ 4 mm
Drive capability up to 800 Ω
Fail-safe: < 3 mA indicates open-circuit or probe fault
Mechanical & Environmental
Cable: 10 m PTFE-insulated, stainless-steel-braided coax
Operating Temp: –25 °C to +65 °C; Storage: –40 °C to +85 °C
Shock & Vibration: 6 g half-sine, 11 ms; 5–35 Hz @ 0.15 mm / > 35 Hz @ 1 g
Humidity: Up to 95 % non-condensing
Mounting: Hot-swappable into any VM600 backplane slot
Safety & Approvals
Designed for safe-area use; pairs with external IS barriers when required

Key Features
VOGI

4–20 mA Loop-Only Output
Simplifies wiring and integration—ideal for long‐distance runs and PLC/DCS analog inputs.
Fail-safe behavior (< 3 mA) flags open/short faults without additional wiring.
Wideband Precision
DC–20 kHz flat response captures both slow shaft displacements and high-frequency vibration.
≤ 1 % linearity over full 0–4 mm range ensures accurate gap measurement.
Extended Probe Cable
Built-in 10 m low-capacitance cable preserves signal fidelity in large machinery rooms.
Robust PTFE insulation and steel braid resist chemicals, abrasion, and EMI.
Built-In Fault Detection
On-board diagnostics drive loop current below 3 mA on open or short.
Front-panel LED provides a quick “OK” vs. fault status indication, even during hot-swap.
Modular Hot-Swap Design
VM600 6 U form factor; can be inserted/removed under power without disrupting the rack.
Optional conformal coating available for harsh or corrosive environments.
Seamless VM600 Integration
Rear-plane connection supplies power and routes loop output to I/O modules or DCS.
Compatible with VibroSight via external modules that convert loop signals to digital data

Freight Estimation(Part Of The Area)VOGI

Destination

Freight

Middle East

$42

Southeast Asia

$15

South Asia

$55

South Africa

$47

Europe and USA

$27

Russia

$50


Applications

VOGI

Steam-Turbine Journal Bearing Monitoring
Two TQ401 probes on vertical/horizontal axes feed separate IQS450 B23 modules.
4–20 mA loops tie directly into turbine control PLCs, triggering alarms if eccentricity exceeds limits during startup or load changes.
Gas-Compression Train Air-Gap Control
A TQ401 at the compressor impeller face monitors clearance; IQS450 loop output drives emergency load-shedding logic when gap < 0.5 mm.
Maintains safe operation without requiring complex voltage-bus wiring.
Hydroelectric Generator Rotor Positioning
Probes on runner bearings feed IQS450; loop outputs integrate with SCADA for continuous shaft-center tracking and DCS interlocks.
Enables early detection of thermal bow or draft tube resonance without direct VM600 bus connections.