Vogi International Trading Co., Ltd.
Email: sales4@vogi-interl.com/sales9@vogi-interl.com
Tel: +86 19065187381
Leave Your Message
Vibro-Meter IQS450 204-450-000-001 A1-B31-H05-I0 Proximity measuring system
VIBRO-METER

Vibro-Meter IQS450 204-450-000-001 A1-B31-H05-I0 Proximity measuring system

  • Brand Vibro meter
  • Module Number IQS450
  • Ordering Number 204-450-000-001 A1-B21-H10-I0
  • Country Of Origin Switzerland
  • Dimension 160 × 160 × 120 mm
  • Weight 0.5 kg
  • HS Code 9033000090
  • Condition Brand New
  • Certificate COO TEST REPORT WARRANTY LETTER
  • Warranty 12 Months
  • Inventory Qty 5
  • Payment Term T/T

Technical ParametersVOGI

Part Number & Configuration
Base PN: 204-450-000 001
Suffix A1-B31-H05-I0 Details:
A1: Designed for TQ401-series probes (noncontact, 0–4 mm)
B31: Outputs a 0–10 V DC span (voltage-mode)
H05: Built-in 5 m coaxial cable to the probe
I0: Standard (no intrinsic-safety barrier inside module)
Probe Drive & Input
Excitation Voltage: –20 V DC to –32 V DC supply (draw ≈ 13 mA) for TQ401 probe
Probe Span: 0–4 mm (linear over full range)
Output Linearity: ≤ ± 1 % full scale (with matched probe)
Output Signals
Voltage Output (B31): 0–10 V DC proportional to 0–4 mm gap
Output impedance ≈ 500 Ω
Optional Current Mode (B32): 4–20 mA loop (if selected instead of B31)
Drive capability up to 800 Ω load
Frequency Response
DC to 20 kHz (–3 dB), capturing both slow positional changes and high-frequency vibration
Environmental & Mechanical
Operating Temperature: –25 °C to +65 °C
Storage Temperature: –40 °C to +85 °C
Shock: 6 g half-sine, 11 ms (IEC 68-2-27)
Vibration: 5–35 Hz at 0.15 mm; > 35 Hz at 1 g (IEC 68-2-6)
Humidity: Up to 95 % noncondensing
Mounting: Hot-swappable into any VM600 backplane slot
Approval & Safety
Designed for use in safe areas; pairs with external intrinsic-safety barriers if required for hazardous zones

Key Features
VOGI

Integrated Probe Excitation & Linearization
Supplies stable constant-current drive to a TQ401 probe (0–4 mm), ensuring precise gap sensing.
On-board linearization and temperature compensation guarantee ≤ 1 % nonlinearity over full span.
Wide Bandwidth & High Resolution
DC–20 kHz flat response enables simultaneous monitoring of slow shaft position drift and high-frequency vibration.
Resolution better than 1 µm for precise shaft-centerline detection.
Selectable Output Modes
Standard 0–10 V DC output (B31) for direct connection to VM600 cards, PLC analog inputs, or data-acquisition systems.
Optional 4–20 mA mode (B32) for long-distance loops or intrinsically safe circuits.
High output drive (up to 800 Ω in current mode) allows flexible wiring.
Built-In Fault Detection
Monitors probe-to-conditioning continuity: open-circuit or short-circuit conditions drive output to a defined “fault” voltage (e.g., > 10 V) or “fault” current (< 4 mA), triggering immediate alarm.
LED indicator on front panel shows “OK” status vs. fault.
Compact, Rugged Construction
VM600 6 U form factor, hot-swappable under power to minimize downtime.
Conformal-coated PCBs available for high-humidity or corrosive environments.
EMC/EMI immunity per IEC 61000-6-2, emissions per IEC 61000-6-4.
Seamless VM600 Integration
Rear-plane connection to backplane supplies power and raw analog bus for routed signals.
Conditioned 0–10 V output is available on the VM600 Raw Bus—ideal for feeding MPC4 protection cards or CMC16 condition-monitoring cards.
Compatible with VibroSight software via VM600 backplane for trending and diagnostics.

Freight Estimation(Part Of The Area)VOGI

Destination

Freight

Middle East

$42

Southeast Asia

$15

South Asia

$55

South Africa

$47

Europe and USA

$27

Russia

$50


Applications

VOGI

Steam-Turbine Journal Bearing Monitoring
Two TQ401 probes mounted on vertical/horizontal axes of a high-speed turbine bearing feed separate IQS450 modules.
Continuous 0–10 V position outputs go to VM600 MPC4 for fast trip if eccentricity exceeds safe limits.
Operators track subtle shaft drift during startup, preventing rubbing and bearing damage.
Compressor Rotor Air-Gap Control
In a gas-compression train, a TQ401 probe at the impeller face monitors air-gap clearance.
IQS450’s fast DC–20 kHz response detects sudden gap reductions (indicative of blade rubs or excessive thrust).
Protected by VM600 logic: on gap < 0.5 mm, control system immediately reduces load.

SEND INQUIRYVOGI