Vibro-Meter IQS450 204-450-000-002 A1-B21-H05-I0 Signal Conditioner
Technical ParametersVOGI
Part Number & Configuration
Base PN: 204-450-000 002
Suffix A1-B21-H05-I0:
A1: Supports TQ401-series probes (0–4 mm span)
B21: Dual outputs 4–20 mA loop & 0–10 V raw bus
H05: Integral 5 m coaxial cable to probe
I0: Standard (no intrinsic-safety barrier)
Probe Excitation & Input
Drive Voltage: –20 V to –32 V DC (≈ 13 mA)
Measuring Range: 0–4 mm linear (≤ 1 % non-linearity with matched probe)
Frequency Response: DC–20 kHz (captures slow position shifts and high-frequency vibration)
Output Signals
4–20 mA Loop:
Scaled 4 mA @ 0 mm → 20 mA @ 4 mm
Drive up to 800 Ω; < 3 mA indicates open/short fault
0–10 V Raw Bus:
Buffered 0 V @ 0 mm → 10 V @ 4 mm
Output impedance ~ 500 Ω
Mechanical & Environmental
Cable: 5 m PTFE-insulated, stainless-steel braided coax
Operating Temp: –25 °C to +65 °C; Storage: –40 °C to +85 °C
Shock: 6 g half-sine, 11 ms; Vibration: 5–35 Hz @ 0.15 mm / > 35 Hz @ 1 g
Humidity: Up to 95 % non-condensing
Safety & Approvals
Designed for safe-area use; pairs with external barriers for hazardous zones
Key Features
VOGI
Dual-Output Flexibility
Enables both loop-current (4–20 mA) integration into DCS/PLC and raw-bus voltage for VM600 protection cards or data acquisition.
Wideband Precision
Flat DC–20 kHz response supports simultaneous monitoring of slow shaft drift and high-frequency vibration without external filters.
Compact Hot-Swap Design
VM600 form factor allows insertion/removal under power—minimizing downtime during maintenance.
Integrated Fault Diagnostics
Loop current < 3 mA and raw-bus > 10 V flag probe open/short; front-panel LED shows “OK” vs. fault status.
Robust Cabling & Construction
5 m low-capacitance cable with PTFE insulation and steel braid for reliable performance in harsh industrial environments.
Freight Estimation(Part Of The Area)VOGI
Destination |
Freight |
Middle East |
$42 |
Southeast Asia |
$15 |
South Asia |
$55 |
South Africa |
$47 |
Europe and USA |
$27 |
Russia |
$50 |
Applications
VOGI
Steam-Turbine Journal Bearing Monitoring
Two TQ401 probes feed IQS450 modules; 4–20 mA loops into the DCS enforce eccentricity interlocks, while 0–10 V raw-bus drives VM600 MPC4 for fast trips if shaft drift exceeds setpoints.
Gas-Compressor Air-Gap Control
A TQ401 at the compressor impeller face monitors clearance; loop output to PLC triggers load reduction on gap < 0.5 mm, raw-bus 0–10 V feeds CMC16 for trend logging of slow gap changes.