Vibro-Meter IQS900 204-900-000-011 A1-B21-C1-H05-I0 signal conditioner
Technical ParametersVOGI
Part Number & Configuration
204-900-000-011 with suffix A1-B21-C1-H05-I0
A1: IQS900 series combined proximity/vibration conditioner
B21: Dual outputs – 4–20 mA loop & 0–10 V raw-bus
C1: Single-channel
H05: 5 m integral low-capacitance PTFE cable
I0: Standard (no intrinsic-safety barrier)
IQS900 204-900-000-011 A1-B21-C1-H05-I0 Inputs
Proximity: 0–4 mm eddy-current probe interface (constant-current drive, –20 V to –32 V DC @ 13 mA)
Vibration: IEPE accelerometer or velocity transducer input (24 V DC @ 4 mA excitation)
Signal Conditioning
Proximity Span: 0–4 mm linearized (≤ 1 % non-linearity)
Vibration Bandwidth: DC–20 kHz (–3 dB) with selectable high-pass and low-pass cutoffs
Integration: Digital integration/derivation for acceleration, velocity, or displacement modes
IQS900 204-900-000-011 A1-B21-C1-H05-I0 Outputs
4–20 mA Loop: Scaled to active sensor mode (gap or vibration RMS), with < 3 mA on fault
0–10 V Raw Bus: Buffered analog (0 V at zero to 10 V at full-scale) for backplane
IQS900 204-900-000-011 A1-B21-C1-H05-I0 distribution
IQS900 204-900-000-011 A1-B21-C1-H05-I0 distribution
Fault Flags: Loop current < 3 mA and raw-bus > 10 V indicate sensor or cable fault
Diagnostics & Status
Front-panel LEDs for “OK”, “Fault”, and active mode (Prox or Vibe)
Automatic self-test of sensor continuity and internal electronics
Hot-swap capable without disturbing adjacent rack cards
Mechanical & Environmental
Operating: –25 °C to +65 °C; storage: –40 °C to +85 °C; humidity ≤ 95 % non-condensing
Shock/vibration per IEC 60068-2; ingress IP20
Key Features
VOGI
Combined Proximity & Vibration in One Card
Simplifies rack layouts by conditioning both gap and vibration on a single module.
Dual-Mode Outputs
4–20 mA loop for PLC/DCS integration plus 0–10 V raw-bus for VM600 protection/trending cards.
Wide-Band Vibration Capture
DC–20 kHz response with programmable filters for tailored monitoring of bearing faults, gear meshes, or structural resonances.
Integrated Health Diagnostics
Continuous self-monitoring with clear LED and loop-current fault indication to detect sensor breaks or cable faults.
Field-Ready Cable
5 m PTFE-insulated, low-capacitance cable maintains signal fidelity without external junctions.
Seamless VM600 Integration
Rear-plane bus delivers power and signal routing to downstream MPC/CMC modules and VibroSight software.
Freight Estimation(Part Of The Area)VOGI
Destination |
Freight |
Middle East |
$42 |
Southeast Asia |
$15 |
South Asia |
$55 |
South Africa |
$47 |
Europe and USA |
$27 |
Russia |
$50 |
Applications
VOGI
Turbine Journal Bearing Protection
Conditions two proximity probes for shaft eccentricity and an accelerometer for housing vibration; loop outputs enforce PLC trips, raw bus to MPC4 for fast trip logic.
Compressor Shaft Health
Monitors impeller air-gap and high-frequency vibration on the casing; alarms drive automatic load shedding, while raw-bus data feeds trend analysis of gear-mesh frequencies.
Hydro-Generator Startup Monitoring
Single IQS900 in pit captures both slow thermal bow via proximity and transient vibration spikes during load changes, providing early warnings of rubs or resonances.